View Featured Offers >>
45943
Peptide Desalting C18 StageTip
Proteomic Analysis Products
Miscellaneous

Peptide Desalting C18 StageTip #45943

Citations (0)
Base peak chromatograms (left) of tryptic peptides derived from human MKN-45 gastric carcinoma cancer cell line that were prepared with Peptide Desalting C18 StageTips.  Approximately 110 ng of peptides were analyzed on Orbitrap Q Exactive mass spectrometer and resolved using a 45 min reversed-phase gradient from 7.5% to 32% acetonitrile on a C18 column.  MS1 peak areas (right) of approximately 1,000 unique peptides randomly selected from the StageTip desalted dataset were compared using Skyline software between two replicates.

Storage

This product is stable for at least 36 months when stored at the recommended temperature. Store at room temperature.

Protocol

PRINT

View >Collapse >

General Peptide Desalting Protocol

PTM Peptide IP

Concentration and Purification of Peptides for LCMS Analysis on C18 Tip

NOTE: There are many routine methods for concentrating peptides using commercial products such as C18 tips that have been optimized for peptide desalting/concentration. Regardless of the particular method, we recommend that the method of choice be optimized for recovery and be amenable to peptide loading capacities of at least 10 µg input sample, for instance eluate from PTMScan® immunoaffinity purification (IAP).

A. Solutions and Reagents

    NOTE: Prepare solutions with LC-MS grade water (Cell Signaling Technology, #27732). Organic solvents (trifluoroacetic acid, acetonitrile) should be of the highest grade.

    Prepare all solutions in containers that have never been autoclaved or exposed to soap, as detergents will interfere with LCMS analysis. All percentage specifications for solutions are volume/volume.

  1. StageTip Wetting Solution (0.1% trifluoroacetic acid, 50% acetonitrile)
  2. StageTip Equilibration & Washing Solution (0.1% trifluoroacetic acid)
  3. StageTip Elution Solution (0.1% trifluoroacetic acid, 40% acetonitrile)

    NOTE: Organic solvents are volatile. Tubes containing small volumes of these solutions should be prepared immediately before use and should remain capped as much as possible to prevent evaporation of organic components.

Equipment Not Included:
  1. 1.5 mL microcentrifuge tubes
  2. Centrifuge capable of handling 1.5 mL tubes
  3. StageTip adaptors (Cell Signaling Technology, #58992)
  4. Vacuum concentrator (Speed-Vac)

B. Procedure

    NOTE: All centrifugation steps in this section should be carried out at room temperature. Spin at a speed up to 2,000 x g, such that all of the solution passes through the tip in approximately 3 min. If necessary, spin for longer duration until entire solution passes through tip.

  1. Cut the lid off of a 1.5 mL tube and place an adaptor on top. Place a C18 tip in the adaptor (Cell Signaling Technology, #58992). There should be enough room in the tube to collect ~100 µL of liquid without touching the C18 material at the bottom of the tip.
  2. Equilibrate the C18 tip by pipetting 50 µL of StageTip Wetting Solution into the tip and centrifuging at 2,000 x g for approximately 3 min or until all of the solution has passed through. Transfer the C18 tip to a clean collection tube.
  3. Add 50 µL of StageTip Equilibration and Washing Solution and centrifuge 3 min or until all of the solution has passed through. Repeat this step once for two total Equilibration & Washing steps. Discard flowthrough.
  4. Load sample by centrifuging IAP eluate (approximately 100 µL initial total volume) through the C18 tip. Load IAP eluate 50 µL at a time for a total of two loading steps. Users may re-load the same 50 µL of eluate that passed through the C18 tip one additional time for a total of four loading steps. Modified peptides will be bound to C18 tip. Discard flowthrough after loading is complete. Confirm all of the solution has passed through after each loading step.
  5. Wash the C18 tip by passing 50 µL of StageTip Equilibration and Washing Solution. Repeat this step once for two total Equilibration & Washing steps. Confirm all of the solution has passed through after each wash step. Discard flowthrough and transfer C18 tip to a clean collection tube.
  6. Elute peptides off the C18 tip by centrifuging 10 µL of Stagetip Elution Solution. Repeat this step once for two total elutions. Confirm all of the solution has passed through after each elution step. Pool the two resulting eluates for a final volume of 20 µL.
  7. Dry down the C18 tip eluate from the C18 tip purification in a vacuum concentrator (Speed-Vac) and store the dry peptides at -20°C until LCMS analysis will begin. At that time, re-dissolve the peptides in an appropriate solvent for LCMS analysis such as 5% acetonitrile, 0.1% TFA, 94.9% water (MS grade).

Protocol Id: 3004

Product Description

Peptide Desalting C18 StageTips are solid phase extraction tips that bind to peptides. This product provides 96 individual StageTips that can be used to concentrate and purify peptides eluted from PTMScan® beads prior to liquid chromatography-mass spectrometry (LCMS) analysis.

Background

Reversed-phase chromatography is an important technique for analytical and preparative biochemical separation and purification. Hydrophobic peptides can be concentrated and purified by reversed-phase chromatography with excellent recovery. Peptide Desalting C18 StageTips use the same basic mechanism of reversed-phase chromatography in a convenient format to process peptide samples for LCMS analysis (1).

Limited Uses

Except as otherwise expressly agreed in a writing signed by a legally authorized representative of CST, the following terms apply to Products provided by CST, its affiliates or its distributors. Any Customer's terms and conditions that are in addition to, or different from, those contained herein, unless separately accepted in writing by a legally authorized representative of CST, are rejected and are of no force or effect.

Products are labeled with For Research Use Only or a similar labeling statement and have not been approved, cleared, or licensed by the FDA or other regulatory foreign or domestic entity, for any purpose. Customer shall not use any Product for any diagnostic or therapeutic purpose, or otherwise in any manner that conflicts with its labeling statement. Products sold or licensed by CST are provided for Customer as the end-user and solely for research and development uses. Any use of Product for diagnostic, prophylactic or therapeutic purposes, or any purchase of Product for resale (alone or as a component) or other commercial purpose, requires a separate license from CST. Customer shall (a) not sell, license, loan, donate or otherwise transfer or make available any Product to any third party, whether alone or in combination with other materials, or use the Products to manufacture any commercial products, (b) not copy, modify, reverse engineer, decompile, disassemble or otherwise attempt to discover the underlying structure or technology of the Products, or use the Products for the purpose of developing any products or services that would compete with CST products or services, (c) not alter or remove from the Products any trademarks, trade names, logos, patent or copyright notices or markings, (d) use the Products solely in accordance with CST Product Terms of Sale and any applicable documentation, and (e) comply with any license, terms of service or similar agreement with respect to any third party products or services used by Customer in connection with the Products.

For Research Use Only. Not for Use in Diagnostic Procedures.